Gases to be detected |
Arbitrary combination of 1 ~ 6 types of gases such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on. Optional configuration: temperature and humidity measurements. |
||||
Application
scenarios |
All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on. |
||||
Detection range |
0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL, 20%, 50%, 100%Vol, can be selected; and other ranges can be customized. |
||||
Resolution |
0.01ppm or 0.001ppm (0 ~ 10 ppm);0.01ppm (0 ~ 100 ppm), 0.1ppm (0 ~ 1000 ppm), 1ppm (0 ~ 10000 ppm or more), 0.01 mg/l (0 ~ 200 mg/l), 0.1% LEL, 0.01%, 0.001% Vol |
||||
Detection principle |
Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand. |
||||
Sensor service life |
Electrochemical principle: 2 ~ 3 years; Oxygen gas: 2 years or 6 years can be selected; infrared principle: 5 ~ 10 years; catalytic combustion: 3 years; thermal conductivity: 5 years; PID photoionization: 2 ~ 3 years. |
||||
Allowable error |
≤±1% F.S (other precision levels can be customized) |
||||
Linearity |
≤±1% |
Repeatability |
≤±1% |
Uncertainty |
≤±1% |
Response time |
T90≤20 seconds |
Recovery time |
≤30 seconds |
||
Working environment |
Temperature:-40℃~+70℃,humidity:≤10~95%RH,and built-in filters can be used in high humidity or high dust environment. |
||||
Sample gas temperature |
-40 ℃ ~ + 70 ℃, and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the temperature of 1300 ℃. |
||||
Temperature and humidity measurement |
Optional configuration: temperature at -40 ℃ ~ + 70 ℃, accuracy level at 0.5 ℃; humidity at 0 ~ 100% RH, precision level at 3 % RH |
||||
Power supply |
3.7VDC, 6000mA high capacity rechargeable polymer battery |
||||
Display mode |
2.5-inch high-definition color screen |
||||
Detection mode |
Built-in pump-suction type measurement, and flow rate at 500 ml / min. Calibration flow rate should be greater than 500 ml / min, three-way pipe should be connected, so as to ensure that the excessive gas will be discharged from the bypass. |
||||
Alarm mode |
It is possible to set as sound & light alarm, vibration alarm, sound & light + vibration alarm, turning off the alarm. |
||||
Communication interface |
USB (charging and communication),optional: RS232, infrared communication, automatic recognition |
||||
Data storage |
Standard configuration is the data storage capacity for 100, 000 entries; SD card storage function is optional configuration |
||||
Protection level |
IP67 |
||||
Explosion-proof type |
Intrinsically safe type |
||||
Explosion-proof mark |
Ex ia IIC T4 Ga |
||||
Exterior dimensions |
195×77×46mm(L×W×H) |
||||
Weight |
350g |
||||
Standard accessories |
Manual, qualification certificate, warranty card, USB charger (including the data cable), high-grade aluminum instrument case, belt clip, humidity dust filter |
||||
Optional items |
Temperature and humidity measurement function, 1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1 meter), 0.4 meter stainless steel sampling handle (with dust filter, not retractable), high temperature sampling and cooling filter handle, high temperature humidity pretreatment system, multiple humidity dust filter, hanging rope, CD-ROM (upper level computer communication software), external mini wireless infrared printer |
||||
Detection mode |
Built-in pump-suction type measurement, and flow rate at 500 ml / min. Calibration flow rate should be greater than 500 ml / min, three-way pipe should be connected, so as to ensure that the excessive gas will be discharged from the bypass |
Gases |
Range |
accuracy |
response time |
Principle |
|
oxygen (O2) |
0-30%/100%VOL |
<±3%(F.S) |
0.1%VOL |
<15s |
EC |
combustible gas (Ex) |
0-100%LEL |
<±3%(F.S) |
0.1%LEL |
<10s |
Catalytic Oxidation |
0-100%LEL/VOL |
<±3%(F.S) |
0.1%LEL/VOL |
<10s |
NDIR |
|
carbon oxide (CO) |
0—1000/2000ppm |
<±3%(F.S) |
0.1ppm |
<25s |
EC |
hydrogen sulfide (H2S) |
0-100/2000ppm |
<±3%(F.S) |
0.1/1ppm |
<30s |
EC |
sulfur dioxide (SO2) |
0-100ppm |
<±3%(F.S) |
0.1ppm |
<30s |
EC |
Nitric Oxide (NO) |
0-250ppm |
<±3%(F.S) |
1ppm |
<30s |
EC |
nitrogen dioxide (NO2) |
0-20ppm |
<±3%(F.S) |
0.1ppm |
<60s |
EC |
Chlorine (Cl2) |
0-20ppm |
<±3%(F.S) |
0.1ppm |
<30s |
EC |
Ammonia (NH3) |
0-100ppm |
<±3%(F.S) |
0.1/1ppm |
<50s |
EC |
hydrogen (H2) |
0-1000ppm |
<±3%(F.S) |
1ppm |
<60s |
EC |
hydrogen cyanide(HCN) |
0-50ppm |
<±3%(F.S) |
0.1ppm |
<100s |
EC |
hydrogen chloride (HCl) |
0-20ppm |
<±3%(F.S) |
0.1ppm |
<60s |
EC |
hydrogen phosphide(PH3) |
0-20ppm/1000ppm |
<±3%(F.S) |
0. 1ppm |
<25s |
EC |
Ozone (O3) |
0-20ppm |
<±3%(F.S) |
0.01ppm |
<30s |
EC |
chlorine dioxide (ClO2) |
0-20ppm |
<±3%(F.S) |
0.1ppm |
<30s |
EC |
ethylene oxide (C2H4O,ETO) |
0-100ppm |
<±3%(F.S) |
0.1ppm |
<45s |
EC |
Formaldehyde (CH2O) |
0-20ppm |
<±3%(F.S) |
0.01ppm |
<30s |
EC |
silane(SiH4 ) |
0-50ppm |
<±3%(F.S) |
0.1ppm |
<60s |
EC |
hydrogen fluoride (HF) |
0-10ppm |
<±3%(F.S) |
0.1ppm |
<60s |
EC |
fluorine (F2 ) |
0-1ppm |
<±3%(F.S) |
0.01ppm |
<60s |
EC |
Phosgene (COCl2 ) |
0-1ppm |
<±3%(F.S) |
0.01ppm |
<60s |
EC |
Total Volatile Organic Compound gases ( TVOC ) |
0-10/100/2000ppm |
<±2%(F.S) |
0.01/0.01/0.1ppm |
<30s |
EC |
Total Volatile Organic Compound gases ( TVOC ) |
0-10/100/2000ppm |
<±2%(F.S) |
0.01/0.01/0.1ppm |
<30s |
PID |
Ningxia Maiya
The Pumping portable 6 in 1 fuel is alarm multi O2 H2S CO CH4 gasoline drip detector CO2 gas analyzers replace MSA BW is one thing this must-have anyone whom needs to detects gas leaks and keep their work environment safe. Manufactured by Ningxia Maiya, a continuing business is continuing due to the top-quality and goods are dependable and it is also made become very an easy task to utilize and efficient.
Well suited for usage in many companies, including construction, mining, and coal and oil. The detector is preparing to identify an array of gases, including LEL, O2, H2S, CO, CH4, and CO2 with six different sensors. The detector is likewise in a situation to gauges the known degrees of the gas, offering you and reading is accurate of gas levels in your environments.
Portable. Compact and lightweight, making this very easy to take you determine to opt for you wherever. A pump is roofed it really safer much more straightforward to found in dangerous environments because of it is allows which might be built-in to surely you need to take atmosphere examples through the distances, this means.
Another function is its security measures. Has both visual alarms are audible will trigger whenever the gas levels reach dangerous levels. This provides you having a complete lot is complete to evacuate the location is specific take action to fixes the down sides.
Easy task to steadfastly keep up. Includes a battery is lasts are rechargeable approximately 12 hours for a fee is solitary. It has a durable, water-resistant shell that could withstands the rigors of day-to-day uses.
The Pumping portable 6 in 1 gasoline is alarm multi O2 H2S CO CH4 gasoline drip detector CO2 gas analyzers replace MSA BW from Ningxia Maiya is an investment is wonderful whoever needs to identify gasoline leaks and keep their work environments safe.