All Categories

Get in touch

Portable gas detector

Home >  Products >  Portable gas detector

MST600P Pumping portable 6 in 1 multi gas detector replace MSA BW

MST600P Pumping portable 6 in 1 multi gas detector replace MSA BW

  • Overview
  • Related Products
Product Description
The portable composite gas detector can be used in: mobile rapid and accurate detection of a variety of gas concentration and measurement of
environmental temperature and humidity, if the measurement exceeded the limit value, the alarm will sound. adopted 2.5-inch high-definition color screen for real-
time display, adopted the gas sensors of internationally well-known brands, and the main detection principles include: electrochemical, infrared, catalytic
combustion, thermal conductivity, PID photoionization, and so on. Adopted Swiss high-precision capacitive digital temperature and humidity sensors.
Advanced electric circuit design, mature kernel algorithm processing, unique external appearance design, had achieved a number of patents about the
software works, external appearance, and so on. is suitable for detecting the concentrations of gases in the atmosphere environment in the pipeline or
confined space; and the purity of the gas leakage and various high concentration single gases with the background gas as nitrogen gas or oxygen gas. The types
for detection are more than 500 types.

 MST600P Pumping portable 6 in 1 multi gas detector replace MSA BW detailsMST600P Pumping portable 6 in 1 multi gas detector replace MSA BW factory     MST600P Pumping portable 6 in 1 multi gas detector replace MSA BW supplierMST600P Pumping portable 6 in 1 multi gas detector replace MSA BW details

 

 

Feature and Benefits
  •  Rich human-machine interface
  •  It is possible to simultaneously detect 1 ~ 6 types of gases, and the units can be switched freely
  •  Function of large-capacity data storage (capacity can be customized)
  •  Various kinds of communication interfaces and printing functions
  •  High temperature gas detection (optional) The optional high-temperature
  •  Graphical display, and use the form of curve to reflect the trend of gas concentration changes in a certain period of time
  •  Data recovery function; in case of mis-operation, it is possible to select partial or full recovery
  •  It is possible to set whether to display the maximum value, minimum value, average value or not
  •  Standard USB charging port, with charging protection function, USB hot-plug supported, and the charging status instrument can work properly
  • 6000mA high capacity rechargeable polymer battery is adopted, so it is possible to work for a long period of time
  •  Real-time detection or timing detection is supported; when no detection will be done, it is possible to shut down the pump so as to extend the startup time
  •  Multiple alarm modes, and multi-directional and three-dimensional indication alarm states
  •  Multiple alarm mode settings: low alarm, high alarm, interval alarm, and weighted average alarm
  • Chinese and English interfaces can be selected
  •  Zero-point automatic tracking; long-term use will not be affected by the zero drift
  •  Multi-level calibration for target points, can ensure the linearity and accuracy of the measurements

Technical parameters

Gases to be detected

Arbitrary combination of 1 ~ 6 types of gases such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on.

Optional configuration: temperature and humidity measurements.

Application

 

scenarios

All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.

Detection range

0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL, 20%, 50%, 100%Vol, can be selected; and other ranges can be customized.

Resolution

0.01ppm or 0.001ppm (0 ~ 10 ppm);0.01ppm (0 ~ 100 ppm), 0.1ppm (0 ~ 1000 ppm), 1ppm (0 ~ 10000 ppm or more), 0.01 mg/l (0 ~ 200 mg/l), 0.1% LEL,

0.01%, 0.001% Vol

Detection principle

Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand.

Sensor service life

Electrochemical principle: 2 ~ 3 years; Oxygen gas: 2 years or 6 years can be selected; infrared principle: 5 ~ 10 years; catalytic combustion: 3 years; thermal conductivity: 5 years; PID photoionization: 2 ~ 3 years.

Allowable error

≤±1% F.S (other precision levels can be customized)

Linearity

≤±1%

Repeatability

≤±1%

Uncertainty

≤±1%

Response time

T90≤20 seconds

Recovery time

≤30 seconds

Working

environment

Temperature:-40℃~+70℃,humidity:≤1095%RH,and  built-in filters can be used in high humidity or high dust environment.

Sample gas

temperature

-40 ℃ ~ + 70 ℃, and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the temperature of 1300 ℃.

Temperature

and humidity

measurement

Optional configuration: temperature at -40 ℃ ~ + 70 ℃, accuracy level at 0.5 ℃; humidity at 0 ~ 100% RH, precision level at 3 % RH

Power supply

3.7VDC, 6000mA high capacity rechargeable polymer battery

Display mode

2.5-inch high-definition color screen

Detection mode

Built-in pump-suction type measurement, and flow rate at 500 ml / min. Calibration flow rate should be greater than 500 ml / min, three-way pipe should be connected, so as to ensure that the excessive gas will be discharged from the bypass.

Alarm mode

It is possible to set as sound & light alarm, vibration alarm, sound & light + vibration alarm, turning off the alarm.

Communication

   interface

USB (charging and communication),optional: RS232, infrared communication, automatic recognition

Data storage

Standard configuration is the data storage capacity for 100, 000 entries; SD card storage function is optional configuration

Protection level

IP67

Explosion-proof

type

Intrinsically safe type

Explosion-proof

mark

Ex ia IIC T4 Ga

Exterior

dimensions

195×77×46mm(L×W×H)

Weight

350g

Standard

accessories

Manual, qualification certificate, warranty card, USB charger (including the data cable), high-grade aluminum instrument case, belt clip, humidity dust filter

Optional items

Temperature and humidity measurement function, 1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1 meter), 0.4 meter stainless steel sampling handle (with dust filter, not retractable), high temperature sampling and cooling filter handle, high temperature humidity pretreatment system, multiple humidity dust filter, hanging rope, CD-ROM (upper level computer communication software), external mini wireless infrared printer

Detection mode

Built-in pump-suction type measurement, and flow rate at 500 ml / min. Calibration flow rate should be greater than 500 ml / min, three-way pipe should be connected, so as to ensure that the excessive gas will be discharged from the bypass

Parrt of gases specifications are as follow

Gases

Range

accuracy

resolution

response time

Principle

oxygen (O2)

0-30%/100%VOL

±3%(F.S)

0.1%VOL

<15s

EC

combustible gas

 (Ex)

0-100%LEL

±3%(F.S)

0.1%LEL

<10s

Catalytic

Oxidation

0-100%LEL/VOL

±3%(F.S)

0.1%LEL/VOL

<10s

NDIR

carbon oxide

(CO)

01000/2000ppm

±3%(F.S)

0.1ppm

<25s

EC

hydrogen sulfide

(H2S)

0-100/2000ppm

±3%(F.S)

0.1/1ppm

<30s

EC

sulfur dioxide

(SO2)

0-100ppm

±3%(F.S)

0.1ppm

<30s

EC

Nitric Oxide

(NO)

0-250ppm

±3%(F.S)

1ppm

<30s

EC

nitrogen dioxide

(NO2)

0-20ppm

±3%(F.S)

0.1ppm

<60s

EC

Chlorine

(Cl2)

0-20ppm

±3%(F.S)

0.1ppm

<30s

EC

Ammonia

(NH3)

0-100ppm

±3%(F.S)

0.1/1ppm

<50s

EC

hydrogen

(H2)

0-1000ppm

±3%(F.S)

1ppm

<60s

EC

hydrogen cyanide(HCN)

0-50ppm

±3%(F.S)

0.1ppm

<100s

EC

hydrogen chloride

(HCl)

0-20ppm

±3%(F.S)

0.1ppm

<60s

EC

hydrogen phosphide(PH3)

0-20ppm/1000ppm

±3%(F.S)

0. 1ppm

<25s

EC

Ozone

(O3)

0-20ppm

±3%(F.S)

0.01ppm

<30s

EC

chlorine dioxide

(ClO2)

0-20ppm

±3%(F.S)

0.1ppm

<30s

EC

ethylene oxide

(C2H4O,ETO)

0-100ppm

±3%(F.S)

0.1ppm

<45s

EC

Formaldehyde

(CH2O)

0-20ppm

±3%(F.S)

0.01ppm

<30s

EC

silane(SiH4 )

0-50ppm

±3%(F.S)

0.1ppm

<60s

EC

hydrogen fluoride

(HF)

0-10ppm

±3%(F.S)

0.1ppm

<60s

EC

fluorine

(F2 )

0-1ppm

±3%(F.S)

0.01ppm

<60s

EC

Phosgene

(COCl2 )

0-1ppm

±3%(F.S)

0.01ppm

<60s

EC

Total Volatile Organic

Compound gases

 ( TVOC )

0-10/100/2000ppm

±2%(F.S)

0.01/0.01/0.1ppm

<30s

EC

Total Volatile Organic

Compound gases

 ( TVOC )

0-10/100/2000ppm

±2%(F.S)

0.01/0.01/0.1ppm

<30s

PID

Ningxia Maiya

The Pumping portable 6 in 1 fuel is alarm multi O2 H2S CO CH4 gasoline drip detector CO2 gas analyzers replace MSA BW is one thing this must-have anyone whom needs to detects gas leaks and keep their work environment safe. Manufactured by Ningxia Maiya, a continuing business is continuing due to the top-quality and goods are dependable and it is also made become very an easy task to utilize and efficient.

Well suited for usage in many companies, including construction, mining, and coal and oil. The detector is preparing to identify an array of gases, including LEL, O2, H2S, CO, CH4, and CO2 with six different sensors. The detector is likewise in a situation to gauges the known degrees of the gas, offering you and reading is accurate of gas levels in your environments.

Portable. Compact and lightweight, making this very easy to take you determine to opt for you wherever. A pump is roofed it really safer much more straightforward to found in dangerous environments because of it is allows which might be built-in to surely you need to take atmosphere examples through the distances, this means.

Another function is its security measures. Has both visual alarms are audible will trigger whenever the gas levels reach dangerous levels. This provides you having a complete lot is complete to evacuate the location is specific take action to fixes the down sides.

Easy task to steadfastly keep up. Includes a battery is lasts are rechargeable approximately 12 hours for a fee is solitary.  It has a durable, water-resistant shell that could withstands the rigors of day-to-day uses.

The Pumping portable 6 in 1 gasoline is alarm multi O2 H2S CO CH4 gasoline drip detector CO2 gas analyzers replace MSA BW from Ningxia Maiya is an investment is wonderful whoever needs to identify gasoline leaks and keep their work environments safe.