User Pain Point
1. The NO concentration in exhaled breath detection is as low as tens of PPB, and conventional sensors cannot respond stably.
2. The humidity in exhaled breath reaches more than 95% RH instantly, making the sensor prone to drift or inaccuracy.
3. The zero point is easily disturbed by temperature and humidity background fluctuations, leading to measurement errors.
4. The exhalation scenario involves non-continuous gas exposure, which has extremely high requirements for the response and recovery of the sensor.
5. Multiple devices are used in parallel, requiring batch consistency and long-term stability.
6. Short service life, sensors need to be replaced every 1-2 years, resulting in high after-sales maintenance costs.
DS4-NO Solutions
1. Adopting solid polymer electrochemical technology with ultra-low detection limit (resolution down to 5ppb).
2. Capable of long-term stable operation, resistant to high humidity environments above 95% RH, and no risk of liquid migration in the internal electrode structure.
3. Built-in open zero calibration protocol, adaptable to different background air environments to ensure zero stability.
4. Fast response and fast return to zero, customizable higher sampling frequency to adapt to the pulsed ventilation rhythm of exhalation.
5. Full-scale drift and consistency deviation are both less than ±0.5% FS, meeting the integrated assembly requirements of medical equipment.
6. The solid polymer sensor has a service life of 5-10 years, which can be extended with proper maintenance and cleaning.
Application Scenarios
Auxiliary diagnosis of chronic respiratory diseases (e.g., asthma, COPD
◦ Monitor the degree of airway inflammation using changes in exhaled NO concentration
◦ Conduct joint analysis with lung function data to provide long-term trend support
◦ Realize individualized precision medication evaluation
Early screening and follow-up management of childhood asthma
◦ Exhaled breath detection for children is more inclined to non-invasive and real-time response
◦ The fast response and zero-calibratable characteristics of DS4-NO adapt to screening needs in different places
Exhaled NO monitoring in clinical research
◦ Assist in evaluating patients' responsiveness to drugs or treatment plans
◦ Monitor NO changes during drug trials
Integration into sleep-disordered breathing screening equipment
◦ Changes in NO emission during apnea and hypopnea
◦ Can be built into portable sleep monitoring instruments for real-time data collection
Intelligent health wearable devices/portable detectors
◦ Support low-power Bluetooth/WiFi wireless applications
◦ Connect with smart terminals to realize family health early warning
User Value
• Precisely identify tiny changes in exhaled NO concentration, providing key data support for disease screening and chronic disease management
•Reliable and durable, adaptable to high-humidity and dynamic environments, significantly reducing maintenance and replacement frequency
• Integrated intelligent design, supporting protocol integration and batch deployment, reducing the integrated development cost of equipment manufacturers
• High consistency and low drift, ensuring the stability of long-term use in clinical and scientific research
• Open zero calibration mechanism to meet the needs of precise monitoring in complex environmental backgrounds
Product Selection
DS4-O2-25%-FT
(Application scenarios: Evaluate respiratory function and oxygenation status; intra-operative and post-operative anesthesia monitoring; management of chronic respiratory diseases (COPD, interstitial lung disease); first aid and intensive care (hypoxemia early warning))
DS4-CO-50-FT
(Application scenarios: Smoking status assessment, CO poisoning diagnosis, inflammation/hemoglobin metabolism abnormality monitoring)
DS4-H2-100-FT
(Application scenarios: Lactose/fructose intolerance detection (lactose load test); small intestinal bacterial overgrowth (SIBO) breath test; evaluation of abnormal intestinal fermentation)
DS4-H2S-1-FT
(Application scenarios: Marker of oral malodor (halitosis), metabolite of intestinal sulfur-producing bacteria, related to digestive system diseases and periodontal disease)